Air handling unit for data center cooling

The STULZ CyberHandler is a centralized precision cooling solution that is specially designed to free up space in the data center, allowing more room for IT equipment. The CyberHandler can be mounted on the roof or the exterior wall of the building.

Features

csm_STULZ-CyberHandler-for-Data-Centers_01_9765ed50f4.jpg
  • Modular design

  • Direct & Indirect free cooling available

  • Coil bypass for reducing the loss of air pressure under a low heat load

  • Flexible connections for return air, supply air and outside air ducts

  • Powder-coated aluminum panels – ensure air tightness, protect against reflected sunlight and temperature losses

  • Aluminum housing for corrosion protection and a low weight

  • Maximum energy efficiency for high circulating air and supply air temperatures (in accordance with ASHRAE 90.1)

  • STULZ E² controls – data center specific with user adjustable set-point envelope

csm_STULZ-CyberAir-1080-Data-Center-Cooling-Solution_f7f55a09ef.png

STULZ offers the broadest range of cooling capacities for chilled water (CW) and direct expansion (DX) units on the market.  With 20-1,080 kW of cooling, there is an air conditioner (CRAC) or air handler (CRAH) for every mission critical application.

CRAH - Chilled Water (CW)

  • Largest capacity perimeter CW air handlers in the industry

  • Greater airflow than other solutions

  • Multiple EC Fan options (additional fans in same size cabinet)

  • All EC Fans mounted in the cabinet meet full performance without having to be dropped into the raised floor

  • Fewer units at higher capacity can significantly reduce capital cost and operating cost

  • 2 x CW valves standard on CFD-510 and larger units (option for 1 CW valve)

  • Dehumidification efficiently achieved through reduced air volume at maximum cooling

  • Standard and seismic floor stands available for all CW units

  • Filter plenums designed with increased surface area for filtration, lower pressure drop, and improved energy savings

  • Standard MERV 8 filters (optional up to MERV 14 filters)

  • 100% front access on all sizes

  • Made in the USA

csm_STULZ-Precision-Cooling-Condenser_be62125e98.jpg

CRAC - Direct Expansion (DX)

  • DX systems provided with highly efficient and reliable low noise scroll compressors

  • Single or multi-stage compressor arrangement including tandem configurations

  • Micro plate heat exchangers offer major improvements in heat transfer

  • Optimized AWS/Free-cooling coils to closely match DX cooling capacities, increasing energy savings opportunities

  • Refrigeration-based dehumidification system effectively removes excess moisture

  • Hot gas reheat - provides reheat using recycled compressor heat

  • Snap acting / full floating hot gas bypass system provides cooling capacity modulation and evaporator coil freeze protection

  • Multiple stages of DX cooling to match load requirement

  • Electronic expansion valves can be optimized to work over a wide range of conditions

  • Made in the USA

csm_STULZ-E2-Microprocessor-Controller-for-Data-Center-Precision-Cooling_02_ab918feda4.png

STULZ E2 Control and Monitoring

  • Precise control of temperature and humidity

  • Multiple I/O capabilities for all major components to optimize control for energy savings

  • Supports universal BMS interface for remote monitoring (address readable) and remote control (address writable)

  • Capable of networking controllers in a workgroup (pLAN) to work as one (no BMS required)

  • Pre-engineered controls for economizers and adiabatic cooling